For setting up the camera parameters
It is also possible to import parameters from a file. If you should decide to do this, just click the Import Parameters button.
Once you have finished this last part of the Setup tab, proceed to the Calibration tab.
First, choose the Camera Model you are using:
Even though the camera model Area Scan (Division) typically returns good results for your application, you can improve the accuracy and lower the error rate by using the Area Scan (Polynomial) camera model. We therefore recommend for you to use the Area Scan (Polynomial) model if the Mean Error on the Results tab under Calibration Status is too high. If you decide for the Area Scan (Polynomial) model, it is especially important that you thoroughly cover the field of view with calibration plate images and do not leave out the edges.
Note, that a higher Mean Error might be caused by inappropriate calibration images.
For area scan cameras, the following additional options may be specified:
If your camera has a tilt lens, tick the checkbox Tilt.
Then, the Projection Model must be specified (either Projective or Telecentric).
Telecentric tilt lens cameras are available in different variations, which must be specified in Projection Model:
If you choose a full calibration for an area scan camera, you must specify approximate values for the camera parameters. These parameters depend on the camera type and are listed in the following tables. Please have a look at the data sheet of your camera for suitable values. Information about the focal length can be found on the lens itself.
Parameters for projective area scan cameras:
| Parameter | no tilt | with tilt |
| Cell width | X | X |
| Cell height | X | X |
| Focal length | X | X |
| Image plane distance | X | |
| Tilt angle | X | |
| Rotation angle | X | |
Parameters for telecentric area scan cameras:
| Parameter | no tilt | bilateral | object side | image side |
| Cell width | X | X | X | X |
| Cell height | X | X | X | X |
| Magnification | X | X | X | |
| Focal length | X | |||
| Image plane distance | X | |||
| Tilt angle | X | X | X | |
| Rotation angle | X | X | X | |
Parameters for line scan cameras:
| Parameter | |
| Cell width | X |
| Cell height | X |
| Focal length | X |
| Motion X | X |
| Motion Y | X |
| Motion Z | X |
In the user-defined mode for the area scan camera (division), you can also choose Center Column (Cx), Center Row (Cy) and Kappa. The area scan camera (polynomial) model allows you to also choose the lens distortion parameters for radial distortion Radial 2nd Order (K1), Radial 4th Order (K2), Radial 6th Order (K3) and the two parameters for tangential distortion Tangential 2nd Order (P1) and Tangential 2nd Order (P2).
If you want to change the parameters Cell Width and Cell Hight independently from each other, click the chain button.