Under Quality Issues you find an evaluation of each image, which includes descriptions of the defective image features and a quality score percentage that tells you how severe the problem is. A result of 0% indicates a very defective image feature whereas 100% equals ideal quality. This can help you to improve your calibration result by deleting images which are not good enough and might lead to a higher error rate during the calibration process. If you need a certain quality level you can set a Warn Level and the defects will be listed under Quality Issues. The quality issues are detected by image tests and sequence tests. If you want the program to run faster or if you do not need quality feedback, you can change Image Tests and Sequence Tests either to Quick, which performs less tests, or None, which does not perform any tests at all. If the defects are too severe e.g., if the calibration marks or even the calibration plate are not found, the Calibration button will be grayed out, making it impossible to calibrate unless all images of such poor quality are deleted from the list.
The test results referring to the calibration plate's tilting may be ignored if later measurements are always conducted in exactly the same plane. In this case, however, the values for the Focal Length and Z are not correct each for itself but only in their combination. The reason for this is that neither of these values can be determined for itself which leads to the result that if you get, for example, a Focal Length that is double the value that it should be, Z will be half as high and vice versa. Besides, the further you place an object above the plane in which you have performed the calibration, the less precise the result will be.
Note that poor image quality leads to poor calibration results and subsequently causes bad or wrong measuring values. However, acceptable results are usually achieved even with quality score warnings in the range of 40% to 70%. If necessary check the following tables for suggestions about improving your image quality. When trying to improve your image quality, do not forget to check other error sources.
ATTENTION: If you change your camera setup (aperture, focus, pose) during the calibration process or during the subsequent application, you have to restart your calibration with the new setup. Any changes will result in the failure of the calibration or, even worse, in wrong output values.
Note: Due to special settings or unchangeable specifications of your work environment, it may be possible that you cannot fully avoid any quality reductions. If you follow these instructions, you should, however, be able to reach a feasible quality level to work with.
| Quality Issue | Explanation | Possible Solution |
| Plate is overexposed | Parts of the calibration plate are too bright, which leads to a shifting of edges and therefore calculates a wrong center position. | Close the lens aperture or the shutter a bit more or turn down the brightness of your illumination until an adequate quality is reached. |
| Illumination is inhomogeneous | The image is illuminated inhomogeneously, i.e. the brightness of the calibration plate changes within one image. This condition makes it difficult to locate the calibration plate and consequently leads to a lower accuracy. | Inhomogeneity in an image is often the result of using lateral illumination. If that is the case: Can you change the setting and instead use illumination from above? Another possibility would be to use diffuse illumination. |
| Contrast is low | The difference between the gray values of the calibration plate and the calibration marks is not big enough. | Reasons can be either overexposure or underexposure. To improve your results, change your aperture or the brightness of your illumination. |
| Quality Issue | Explanation | Possible Solution |
| Diameter of marks are too small | The diameters of the found calibration plate marks are too small. | To fix this issue, you should either change your setup or use a calibration plate with larger marks. |
| Marks on plate are out of focus | The marks are not completely focused, some of them appear blurry. This leads to a lower robustness. | The depth of field has to include the whole object. To fix this error, change either your focal length or the distance of the object to the camera. Alternatively you can also make the aperture smaller and use brighter illumination. |
| Quality assessment failed | The image test failed, even though the plate could be found in the image. | For calibration plates with rectangularly arranged marks, check, if any part of the image is occluded and if the occlusion interrupts the black margin of the calibration plate. |
| Mark extraction failed for some images | It was impossible to extract the calibration plate marks in some images, which makes it also impossible to calibrate in this state. | Delete the images for which mark extraction has failed and use new images instead or adapt the extraction parameters. Make sure that you follow the recommendations in the section “How to take a set of suitable images?” in the reference manual chapter “Calibration”. |
| Quality Issue | Explanation | Possible Solution |
| Quality issues detected for some images | The quality of some images is below the warn level. | Check the quality issues of the single images by clicking on their names in the list. Handle quality issues as described in the table above. |
| Number of images is too low | The number of images is lower than recommended. | Check if you have taken enough images, depending on the type of calibration plate you use. |
| Field of view is not covered by plate images | Some part of the field of view is not covered by any image of the calibration plate, i.e. there are areas with no marks. | Press the Show button, which appears in a column named Details, to see all areas in red that are not covered by calibration plate images (compare figure 7.4). Before continuing, add the missing image(s) to your sequence. You can avoid this problem by following the recommendations in the section “How to take a set of suitable images?” in the reference manual chapter “Calibration”. |
| Tilt angles are not covered by sequence | The calibration plate has not been tilted enough. | Add more images of your calibration plate tilted in different directions. For calibration plates with rectangularly arranged marks we recommend tilting the plate in every quadrant of the image twice and vary the tilting direction. |
| Not all image sizes are identical | The image list contains images of different sizes. | You have changed your setup while taking calibration images. Therefore, you should delete those images taken before the change to get useful results back. |
Figure 7.4: Not enough calibration images have been taken. a) and b): calibration sequence consisting of two calibration plate images c) A Show button appears due to the fact that the coverage is not sufficient. d) An image shows which parts of the field of view are not covered by calibration plate images.