Class CodeMeter.CMENABLING_CONTEXT

  • Enclosing class:
    CodeMeter

    public static class CodeMeter.CMENABLING_CONTEXT
    extends java.lang.Object
    CMENABLING_CONTEXT contains enabling data. It can be collected using CmGetInfo with option CM_GEI_ENABLEINFO. It can be used for enabling using CmProgram.
    • Field Summary

      Fields 
      Modifier and Type Field Description
      int disableLevel
      specifies the Disable Level.
      CodeMeter.CMTIME disableTime
      contains disable time in seconds since the 1st January 2000 0:00:00 (UTC).
      byte[] enableAccessCode
      contains the Enable Access Code.
      int enableLevel
      specifies the Enable Level.
      java.lang.String enablePassword
      contains the Enable Password.
      long firmcode
      firmcode contains the Firm Code the enabling block is attached to.
      int flags
      specifies the following states: CM_ELUE_VALID specifies that the Enabling Lookup Entry is a valid structure. CM_ELUE_IFI specifies that the Enabling Block Item of the IFI is used and not of the owning Firm Item. CM_ELUE_REQUIRED specifies that this lookup entry must permit the operation independent to other settings.
      int index
      specifies the EBI Index inside a Firm Item (or IFI).
      int itemType
      specifies the following item types: CM_EC_PRODUCTITEM specifies that the Enabling Block Item is attached to the Product Item. CM_EC_FIRMITEM specifies that the Enabling Block Item is attached to the Firm Item. CM_EC_GLOBALITEM specifies that the Enabling Block Item is attached to the IFI (Implicit Firm Item = Firm Code 0)
      int option
      specifies the following flags.
      long productcode
      productcode contains the Product Code the enabling block is attached to.
      java.lang.String text
      contains the text of the Enabling Block Item.
      int type
      specifies the type of the used enabling.
    • Method Summary

      • Methods inherited from class java.lang.Object

        clone, equals, finalize, getClass, hashCode, notify, notifyAll, toString, wait, wait, wait
    • Field Detail

      • firmcode

        public long firmcode
        firmcode contains the Firm Code the enabling block is attached to.
      • productcode

        public long productcode
        productcode contains the Product Code the enabling block is attached to. In case of value 0 check mbItemType to see if it is attached to Product Item with Product Code 0 or to the Firm Item.
      • option

        public int option
        specifies the following flags.
        • CM_EBI_VALID specifies that the enabling block item is a valid structure.
        • CM_EBI_ENABLED specifies that the block is permanently enabled.
        • CM_EBI_DISABLED specifies that the Disabling Flag of the Enabling Block Item is set and the block is permanently disabled.
        • CM_EBI_TEMPENABLED specifies that the Enabling Block Item is temporarily enabled, independently of the static Enabling Status of the Enable Block Item. For firmware less version 1.18 this option is only permitted if the Enable Block Item is owned by the IFI (Implicit Firm Item = Firm Code 0).
      • index

        public int index
        specifies the EBI Index inside a Firm Item (or IFI).
      • type

        public int type
        specifies the type of the used enabling. This can be one of the following flags:
        • CM_EBI_SIMPLEPIN specifies that Simple Pin enabling is used.
        • CM_EBI_TIMEPIN specifies that Time Pin enabling is used.
      • disableTime

        public CodeMeter.CMTIME disableTime
        contains disable time in seconds since the 1st January 2000 0:00:00 (UTC).
      • text

        public java.lang.String text
        contains the text of the Enabling Block Item. Only available for Time Pin.
      • flags

        public int flags
        specifies the following states:
        • CM_ELUE_VALID specifies that the Enabling Lookup Entry is a valid structure.
        • CM_ELUE_IFI specifies that the Enabling Block Item of the IFI is used and not of the owning Firm Item.
        • CM_ELUE_REQUIRED specifies that this lookup entry must permit the operation independent to other settings.
      • itemType

        public int itemType
        specifies the following item types:
        • CM_EC_PRODUCTITEM specifies that the Enabling Block Item is attached to the Product Item.
        • CM_EC_FIRMITEM specifies that the Enabling Block Item is attached to the Firm Item.
        • CM_EC_GLOBALITEM specifies that the Enabling Block Item is attached to the IFI (Implicit Firm Item = Firm Code 0)
      • enableAccessCode

        public byte[] enableAccessCode
        contains the Enable Access Code. The length must be between 2 and 16, if used. Otherwise it must be null.
      • enablePassword

        public java.lang.String enablePassword
        contains the Enable Password.
      • enableLevel

        public int enableLevel
        specifies the Enable Level. This can be one of the following flags (see mbDisableLevel).
      • disableLevel

        public int disableLevel
        specifies the Disable Level. This can be one of the following flags:
        • CM_ELUE_LOCATE only the reading of the Firm Code, the Product Code, the Enabling Block Table and the Enabling Lookup Table is permitted.
        • CM_ELUE_READ the reading of the Firm Item or Product Item is permitted but no operations.
        • CM_ELUE_ENCRYPT encryption, decryption and signature calculation is permitted but not with modification of the Unit Counter.
        • CM_ELUE_UNITUSE encryption, decryption and signature calculation may change the Unit Counter. In a Firm Item, the Firm Update Counter and the Access Counter may be changed.
        • CM_ELUE_MODIFY all operations are permitted including modification of the properties by update commands.
    • Constructor Detail

      • CMENABLING_CONTEXT

        public CMENABLING_CONTEXT()