uEye Camera Manual Version 4.90
Via the menu uEye > Sharpness measure AOI or via the Toolbar you can measure the image sharpness of an selected AOI. To get a sharpness value the edges in the image are evaluated. The sharpness can only be indicated as a relative value as it depends on the edges in the current image. An image with less edges will reach the sharpness value of an image with a lot of edges.
![]() |
Note in triggered mode that you first define the sharpness measuring area and then capture the image. |
The higher the value, the better the sharpness. The value can be used in comparative measurements to detect changes in the image acquisition of the same object, e.g. caused by readjusted lenses.

Fig. 112: Measuring the image sharpness
In the left bottom of the selected area the current and the maximum sharpness value of the AOI are displayed. A red value indicates that the measured sharpness is insufficient.

Fig. 113: Measuring the image sharpness