Set Fieldbus Output Signal Async

This task sets a fieldbus output variable to a specified target value as soon as the robot leaves a certain region (ROI). Fieldbus output variables are Mikado variables that are synchronized via fieldbus (see Synchronizing PLC variables and Mikado variables). These variables can be identified by the property_synced symbol when synchronization is active.

The task triggers a pre-run stop to prevent incorrect use and then starts monitoring the specified region. This means that it should be called when the robot is already within the ROI, but before the movement to leave the ROI is started.

If the robot is already outside the specified ROI when this task is called, the fieldbus output is immediately set to the target value.

Variables

Name

Type

Description

ROI

ROI

The fieldbus output signal is set when this region is left

Fieldbus variable

Bool, Integer, Double, Pose

Mikado variable synchronized as fieldbus output (Profinet, EtherNet/IP, etc.)

Target value

Bool, Integer, Double, Pose

The value that the fieldbus variable should take on

Hint

Fieldbus variables and target value must be of the same type.

Hint

This task triggers a pre-run stop. This means that all robot movements accumulated from previous tasks are executed and must be completed before this task is executed.